Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/65398
Title: Determination of cadmium in vegetables by sequential injection analysis method using 8-hydroxyquinoline as complexing agent
Authors: Kanokwan Chaiyasing
Boonsom Liawruangrath
Surapol Natakankitkul
Sakchai Satienperakul
Wasan Sirisungworawong
Narabhats Rannurags
Saisunee Liawruangrath
Authors: Kanokwan Chaiyasing
Boonsom Liawruangrath
Surapol Natakankitkul
Sakchai Satienperakul
Wasan Sirisungworawong
Narabhats Rannurags
Saisunee Liawruangrath
Keywords: Biochemistry, Genetics and Molecular Biology;Chemistry;Materials Science;Mathematics;Physics and Astronomy
Issue Date: 1-Mar-2019
Abstract: © 2019, Chiang Mai University. All rights reserved. In the present study, a novel and eco-friendly sequential injection analysis (SIA) system with spectrophotometric detection was developed for determination of Cd(II) in vegetable samples. The method is based on the reaction of 8-hydroxyquinoline with Cd(II) as a less-toxic complexing agent in H2SO4 solution, resulting in a light yellow colored complex monitored at 360 nm. The SIA parameters were optimized to obtain the best sensitivity and minimum reagent consumption. Under the optimum conditions, linear calibration graphs over the ranges of 0.04-1.0 mg L-1 and 1.5-5.0 mg L-1 were established. Due to the limitation of Beer’s law, the maximal absorption of the complex was observed at Cd(II) concentration of 1.0 mg L-1. Above which the absorbance decreased with curvature and started to be linear with low slope. The useful calibration graph for Cd(II) in vegetable sample was the first one. The limit of detection was 0.01 mg L-1, with the intra-day and inter-day precisions were less than 1.5%. The proposed method was successfully applied to the determination of Cd(II) in different vegetable samples (chinese kale, false pakchoi, cabbage, lettuce, cucumbers, coriander, water convolvulus, yard long bean, tomatoes, and potatoes) after appropriate sample pretreatment. The obtained results were in good agreement with those obtained by the ICP-MS standard method, verified by the student t-test at the 95% confidence level.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85068014786&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65398
ISSN: 01252526
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.