Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/65395
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPuttaporn Klaypraserten_US
dc.contributor.authorKritsana Jitmaneeen_US
dc.contributor.authorNapaporn Youngvisesen_US
dc.contributor.authorJaroon Jakmuneeen_US
dc.date.accessioned2019-08-05T04:32:39Z-
dc.date.available2019-08-05T04:32:39Z-
dc.date.issued2019-03-01en_US
dc.identifier.issn01252526en_US
dc.identifier.other2-s2.0-85067934342en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85067934342&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/65395-
dc.description.abstract© 2019, Chiang Mai University. All rights reserved. A simple and low-cost method for determination of total antioxidative capacity (TAC) was developed using a flow injection potentiometric method. The reaction involved the measurement of electrical potential change caused by the disturbance of Ce(IV)/Ce(III) ratio of a redox-reagent solution caused by the reduction of Ce(IV) to Ce(III) by the antioxidant. The optimum condition is as follow: reagent solution contained 0.06 mmol L-1 Ce(IV), 0.01 mmol LS Ce(III), and 0.5 mol L-1 H2SO4, and flow rate of solution of 0.8 mL min-1. A linear calibration graph was 0.08-1.00 mmol L-1 of ascorbic acid equivalent. The system provided good precision, i.e., %RSD (n=11) of 6.0, 1.4, and 4.1 for 0.08, 0.40 and 1.00 mmol L-1 ascorbic acid, respectively. The method was applied to evaluating TAC of tea infusion samples compared with the batch ceric reducing antioxidant capacity (CERAC) method and the batch ferric reducing antioxidant power (FRAP) method. Good correlation of the results between these methods was observed. The developed method is low cost, low reagent consumption, and low waste production. Moreover, it did not suffer from colored and colloidal substances presented in the samples.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectMaterials Scienceen_US
dc.subjectMathematicsen_US
dc.subjectPhysics and Astronomyen_US
dc.titleFlow injection potentiometric method based on Ce(IV)/Ce(III) redox reaction for determination of total antioxidant capacityen_US
dc.typeJournalen_US
article.title.sourcetitleChiang Mai Journal of Scienceen_US
article.volume46en_US
article.stream.affiliationsThammasat Universityen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.