Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/63804
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJaroon Junsomboonen_US
dc.contributor.authorJaroon Jakmuneeen_US
dc.date.accessioned2019-05-07T09:57:19Z-
dc.date.available2019-05-07T09:57:19Z-
dc.date.issued2016en_US
dc.identifier.issn0125-2526en_US
dc.identifier.urihttp://it.science.cmu.ac.th/ejournal/dl.php?journal_id=7370en_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/63804-
dc.description.abstractDifferential pulse anodic stripping voltammetric method has been developed for determination of cadmium and lead released from concrete roofing tiles. The sample was extracted with water for 24 h according to the TIS 535-2540 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of 4% v/v acetic acid solution were put in a voltammetric cell. Then, the solution was stirred at 2000 rpm and purged with nitrogen gas for 3 min before the deposition of the metals was carried out by applying a constant potential of -0.90 V versus Ag/AgCl to a hanging mercury drop electrode (HMDE) for 45 s. After that a differential pulse scanning waveform from -0.90 to -0.10 V was applied and a voltammogram was recorded. Peak current of cadmium and lead were measured at peak potentials of -0.555 and -0.364 V vs Ag/AgCl, respectively. Standard addition procedure was used for quantification. Relative standard deviation for 11 replicate determinations of 8 mgL-1 of both metals were in the range of 1.59 - 1.74%. Percentage recoveries obtained by spiking 8 mgL-1 of cadmium and lead to the sample solution were found to be 107% and with detection limit of 0.15 mgL-1 for both metals. It was found that contents of cadmium and lead released from the concrete roofing tile samples were in the range of < 0.15 - 0.49 mgL-1 and < 0.15 - 11.95 mgL-1, respectively, which are lower than the regulated values of the Thailand industrial standard (TIS 535-2540). The proposed method is simpler, more convenient and more sensitive than the standard method based on an atomic absorption spectrophototometry.en_US
dc.languageEngen_US
dc.publisherScience Faculty of Chiang Mai Universityen_US
dc.titleDetermination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Methoden_US
dc.typeบทความวารสารen_US
article.title.sourcetitleChiang Mai Journal of Scienceen_US
article.volume43en_US
article.stream.affiliationsPhysics and Engineering 2 Sub-division, Physics and Engineering Program, Department of Science Service, Ministry of Science and Technology, Bangkok 10400, Thailand.en_US
article.stream.affiliationsDepartment of Chemistry, and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand.en_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.