Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/63675
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSarawoot Impengen_US
dc.contributor.authorAnchalee Junkaewen_US
dc.contributor.authorPhornphimon Maitaraden_US
dc.contributor.authorNawee Kungwanen_US
dc.contributor.authorDengsong Zhangen_US
dc.contributor.authorLiyi Shien_US
dc.contributor.authorSupawadee Namuangruken_US
dc.date.accessioned2019-03-18T02:23:38Z-
dc.date.available2019-03-18T02:23:38Z-
dc.date.issued2019-04-15en_US
dc.identifier.issn01694332en_US
dc.identifier.other2-s2.0-85059171743en_US
dc.identifier.other10.1016/j.apsusc.2018.12.209en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85059171743&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/63675-
dc.description.abstract© 2018 Elsevier B.V. The feasibility of using a MnN4 moiety embedded graphene (MnN4-GP) as a gas sensor was investigated by density functional theory calculations. Thirteen gas molecules (CO, CO2, NO, NO2, N2O, SO2, NH3, H2O, H2S, CH4, O2, H2 and N2) were considered. The adsorption behaviors of these gases on MnN4-GP were intensively analyzed in terms of adsorption structure, electronic charge, density of states (DOS), magnetic moments and recovery time. Among thirteen gases, NO, NO2, O2, CO and SO2 adsorbed on MnN4-GP showed strong chemisorption energies, calculated to be −2.30, −1.42, −1.32, −1.11 and −0.51 eV, respectively, while the rest of the gases had physisorption interactions with MnN4-GP. Moreover, the strong chemisorption of the four gases drastically changed the DOS of MnN4-GP and pronounced charge transfer between the adsorbed gas and MnN4-GP. Interestingly, the magnetic moment of MnN4-GP was apparently changed from 3.01 µB to 0.13, 1.04 and 2.01 µB, when it was adsorbed by NO, CO and NO2 gases, respectively, while it was hardly altered by other gases. In addition, the calculated recovery times at 423 K of NO, CO and NO2 are 2.5 × 1014 s, 1.7 s and 8275 s, respectively. Such a short recovery time for CO detection makes MnN4-GP interesting as a sensor. When considering all calculated properties, MnN4-GP is proposed as a promising magnetic sensor for CO detection with high selectivity and high sensitivity.en_US
dc.subjectMaterials Scienceen_US
dc.subjectChemistryen_US
dc.subjectPhysics and Astronomyen_US
dc.titleA MnN4 moiety embedded graphene as a magnetic gas sensor for CO detection: A first principle studyen_US
dc.typeJournalen_US
article.title.sourcetitleApplied Surface Scienceen_US
article.volume473en_US
article.stream.affiliationsShanghai Universityen_US
article.stream.affiliationsThailand National Science and Technology Development Agencyen_US
article.stream.affiliationsVidyasirimedhi Institute of Science and Technologyen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.