Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62154
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jaroon Jakmunee | en_US |
dc.contributor.author | Lop Patimapornlert | en_US |
dc.contributor.author | Siripat Suteerapataranon | en_US |
dc.contributor.author | Narong Lenghor | en_US |
dc.contributor.author | Kate Grudpan | en_US |
dc.date.accessioned | 2018-09-11T09:22:46Z | - |
dc.date.available | 2018-09-11T09:22:46Z | - |
dc.date.issued | 2005-02-15 | en_US |
dc.identifier.issn | 00399140 | en_US |
dc.identifier.other | 2-s2.0-10844271306 | en_US |
dc.identifier.other | 10.1016/j.talanta.2004.08.007 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=10844271306&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/62154 | - |
dc.description.abstract | Sequential injection with "Lab-at-Valve (LAV)" approach is demonstrated for potentiometric determination of chloride. The LAV flow-through electrode system consists of two Ag/AgCl electrodes: one as a reference electrode, silver chloride activated surface-silver wire soaked in a constant-concentration chloride ion solution in a small tube covered with a polymer-membrane, another as a working electrode (a similar silver chloride activated surface-silver wire) placed in a flow channel. The electrode system is attached at one port of a 10 port multiposition valve. A modified autoburette was used as a propelling device. Using SI operation via a program written in-house, based on LabVIEW®, a standard/sample is inserted, via the selection valve, in potassium nitrate as an electrolyte and water is used as a carrier. The zones are transported from the holding coil to the flow cell to monitor the difference in potential due to concentration cell behavior. The potential difference is then recorded as a peak. Peak height is proportional to logarithm of chloride concentration. The SI-LAV for chloride determination is very simple, fast, precise, accurate, automatic and economical. Applications to mineral drinking water and surface water have been made. The results agree with those of IC and titrimetric methods. © 2004 Elsevier B.V. All rights reserved. | en_US |
dc.subject | Chemistry | en_US |
dc.title | Sequential injection with lab-at-valve (LAV) approach for potentiometric determination of chloride | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Talanta | en_US |
article.volume | 65 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.