Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Y. Udnan | en_US |
dc.contributor.author | I. D. McKelvie | en_US |
dc.contributor.author | M. R. Grace | en_US |
dc.contributor.author | J. Jakmunee | en_US |
dc.contributor.author | K. Grudpan | en_US |
dc.date.accessioned | 2018-09-11T09:22:42Z | - |
dc.date.available | 2018-09-11T09:22:42Z | - |
dc.date.issued | 2005-04-15 | en_US |
dc.identifier.issn | 00399140 | en_US |
dc.identifier.other | 2-s2.0-17744362273 | en_US |
dc.identifier.other | 10.1016/j.talanta.2004.12.064 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=17744362273&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149 | - |
dc.description.abstract | Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l-1and sample throughput of 70 samples h-1were achieved. The relative standard deviations for 50 and 500 μg P l-1orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l-1was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l-1standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples. © 2005 Elsevier B.V. All rights reserved. | en_US |
dc.subject | Chemistry | en_US |
dc.title | Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Talanta | en_US |
article.volume | 66 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Monash University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.