Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/58749
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | M. Tungjai | en_US |
dc.contributor.author | N. Phathakanon | en_US |
dc.contributor.author | P. Ketnuam | en_US |
dc.contributor.author | J. Tinlapat | en_US |
dc.contributor.author | S. Kothan | en_US |
dc.date.accessioned | 2018-09-05T04:30:10Z | - |
dc.date.available | 2018-09-05T04:30:10Z | - |
dc.date.issued | 2018-01-01 | en_US |
dc.identifier.issn | 23454229 | en_US |
dc.identifier.issn | 23223243 | en_US |
dc.identifier.other | 2-s2.0-85043251772 | en_US |
dc.identifier.other | 10.18869/acadpub.ijrr.16.1.123 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85043251772&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/58749 | - |
dc.description.abstract | Background: People occasionally undergo medical diagnosc X-ray examinaons and expose their red blood cells to radiaon. Radiaon that is generated from medical diagnosc X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnosc X-ray machines. Kilo-voltage influences the radiaon dosage. The aim of this study is to determine the hemolysis, osmoc fragility, and fluorescence anisotropy value on irradiated red blood cells as a funcon of kV during medical diagnosc X-ray examinaons. Materials and Methods: The kV, kilo-voltage that is applied across an X-ray tube, of a medical diagnosc X-ray machine was operated at 50, 70 and 100 kV. We determined the hemolysis, osmoc fragility, and fluorescence anisotropy value in red blood cells at 0.5 and 4 hours post-irradiaon. In order to determine hemolysis and osmoc fragility, the release of hemoglobin was measured by spectrophotometry technique. 1,6-diphenyl-1,3,5-hexatriene (DPH) was used as a molecular probe for determining fluorescence anisotropy value by fluorescence anisotropy technique. Non-irradiated red blood cells served as the control. Results: For the 50, 70, and 100 kV of medical diagnosc X-rays, the hemolysis, osmoc fragility, and fluorescence anisotropy values of irradiated red blood cells at 0.5 and 4 hours post-irradiaon did not significantly change when compared to the control. Conclusion: Our results suggested that 50, 70, and 100 kV of medical diagnosc X -ray did not influence hemolysis, osmoc fragility, and fluorescence anisotropy values of irradiated red blood cells. | en_US |
dc.subject | Health Professions | en_US |
dc.subject | Medicine | en_US |
dc.title | Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | International Journal of Radiation Research | en_US |
article.volume | 16 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.