dc.description.abstract© 2017 Society of Thermal Engineers of Serbia. The objectives of this study are to experimentally investigate the effect of mean-dering turn numbers on thermal performance and to predict the optimum mean-dering turn number of vertical and horizontal closed-loop pulsating heat pipes. The closed-loop pulsating heat pipes were made from a Cu capillary tube with in-ternal diameter of 2.0 mm. The closed-loop pulsating heat pipes were bent into undulating tubes with various meandering turn numbers, such as 5, 7, 10, 16, and 30. Each set of the closed-loop pulsating heat pipes had different evaporator sec-tion lengths of 50 mm and 150 mm. Heat input was supplied to the closed-loop pulsating heat pipe by allowing the flow of distilled water as the heating medium through the evaporator section. The adiabatic section temperature was constant-ly controlled at 50 °C. It could be concluded that the optimum meandering turn number of vertical closed-loop pulsating heat pipes with an evaporator section length of 50 mm is 10 for both R123 and water, and the optimum meandering turn numbers of vertical closed-loop pulsating heat pipes with an evaporator sec-tion length of 150 mm are 5 and 10, respectively, for R123 and water. However, the optimum meandering turn number of the horizontal closed-loop pulsating heat pipes could not be found since the heat flux directly varies with the turn number. In addition, the correlation to predict the optimum meandering turn number of the vertical closed-loop pulsating heat pipes was successfully estab-lished.en_US
dc.subjectEnergyen_US
dc.titleInvestigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipesen_US
dc.typeJournalen_US
article.title.sourcetitleThermal Scienceen_US
article.volume22en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.