Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/58235
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Norrapon Vichiansan | en_US |
dc.contributor.author | Noppakarn Kaai | en_US |
dc.contributor.author | Komgrit Leksakul | en_US |
dc.contributor.author | Saisamorn Lumyong | en_US |
dc.contributor.author | Jeon Geon Han | en_US |
dc.date.accessioned | 2018-09-05T04:21:29Z | - |
dc.date.available | 2018-09-05T04:21:29Z | - |
dc.date.issued | 2018-07-01 | en_US |
dc.identifier.issn | 01252526 | en_US |
dc.identifier.other | 2-s2.0-85050309303 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85050309303&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/58235 | - |
dc.description.abstract | © 2018, Chiang Mai University. All rights reserved. This study examined sterilization of scalpels using plasma technology by comparing the performance effectiveness of two techniques, plasma solution (PS) and plasma dielectric barrier discharge (PDBD), on Escherichia coli and Staphylococcus aureus at 0.5 McFarland. The experimental design was used to determine the optimal condition for both the techniques to be 100% effective by using the ten-fold dilution spread plate count. For PS, the voltage was set at 520 V for 20 s and the concentration of sodium acetate was 1 g/L. For PDBD, the distance between the anodes was 9.4 mm; the discharge time was 14 min; the power was 76 W; and the argon gas flow rate was 22 L/min. On comparing the time taken for 100% sterilization by the two techniques, it was found that PS used less time than PDBD. However, upon testing with Optical Emission Spectrometry (OES), the hydroxyl free radicals produced by PDBD were observed to be greater than those produced by PS. | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Materials Science | en_US |
dc.subject | Mathematics | en_US |
dc.subject | Physics and Astronomy | en_US |
dc.title | Sterilization of medical equipment by plasma technology | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Chiang Mai Journal of Science | en_US |
article.volume | 45 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Thai-Korean Research Collaboration Center (TKRCC) | en_US |
article.stream.affiliations | Sungkyunkwan University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.