Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/58205
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSomchai Lapanantnoppakhunen_US
dc.contributor.authorLucksagoon Ganranooen_US
dc.contributor.authorSupaporn Kradtap Hartwellen_US
dc.contributor.authorKate Grudpanen_US
dc.date.accessioned2018-09-05T04:21:04Z-
dc.date.available2018-09-05T04:21:04Z-
dc.date.issued2018-09-01en_US
dc.identifier.issn16121112en_US
dc.identifier.issn00095893en_US
dc.identifier.other2-s2.0-85050358067en_US
dc.identifier.other10.1007/s10337-018-3575-4en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85050358067&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/58205-
dc.description.abstract© 2018, Springer-Verlag GmbH Germany, part of Springer Nature. A hyphenated sequential injection ion chromatography–flow injection analysis (SIIC–FIA) system is proposed for post column derivatization capable of using murexide, an unstable but commonly available reagent, for the determination of calcium and magnesium in a mixture. A short ion exchange column was modified from a 4.6 mm × 10 mm C18 monolithic guard column. Calcium/magnesium mixture and murexide were used as model analytes and derivatizing agent, respectively. The FIA post column allows the use of unstable chromogenic reagents. The continuous flow of liquid also helped to stabilize the signal baseline during detection. A single concentration based calibration graph was demonstrated. The system requires low volumes of standard/sample (5–50 µL) and mobile phase (4.50 mL), and offers sample throughput at 8 h−1without the need for long column calibration. Detection limits were 0.5 and 0.1 µg for Ca2+and Mg2+, respectively. Working ranges were 1–5 µg Ca2+and 0.2–1 µg Mg2+. Analyses of well and drinking water samples were demonstrated and validated with the standard complexometric titration.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.titleSequential Injection Ion Chromatography with Flow Injection Post Column Derivatization Capable of Using the Unstable Reagent Murexide to Determine Calcium and Magnesium in a Mixtureen_US
dc.typeJournalen_US
article.title.sourcetitleChromatographiaen_US
article.volume81en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsUniversity of Phayaoen_US
article.stream.affiliationsXavier Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.