Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57830
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Akkapong Nitising | en_US |
dc.contributor.author | Keerati Charoontamwong | en_US |
dc.contributor.author | Chumpol Jetjumnong | en_US |
dc.contributor.author | Luckchai Phonwijit | en_US |
dc.contributor.author | Bunpot Sitthinamsuwan | en_US |
dc.date.accessioned | 2018-09-05T03:50:26Z | - |
dc.date.available | 2018-09-05T03:50:26Z | - |
dc.date.issued | 2017-01-01 | en_US |
dc.identifier.issn | 01252208 | en_US |
dc.identifier.other | 2-s2.0-85027277590 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85027277590&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/57830 | - |
dc.description.abstract | © 2017, Medical Association of Thailand. All rights reserved. Background: The C2 pedicle and pars interarticularis complex have distinct anatomy and substantial variation in the population. The exact locations of the C2 pedicle and pars interarticularis are still controversial. Objective: This study aims to determine the safe trajectory and length of C2 pedicle and pars screw insertion. Material and Method: Thirty-six dried cadaveric C2 vertebrae were used in this study. The authors measured four linear and four angular parameters of C2 pedicle and pars interarticularis by using a Vernier caliper and a digital goniometer. Results: Regarding C2 pedicle screw placement, the entry point is a point 5 mm inferior to the superior border of the C2 lamina and 7 mm lateral to the lateral border of the spinal canal, the axial angle is 30°, the sagittal angle is 28° and the length of the distance is 27 mm. For C2 pars screw insertion, the appropriate entry point is a point 3 to 4 mm superior and lateral to the medial aspect of the C2-3 facet joint, the axial angle is 16°, the sagittal angle is 36° and the length of the distance is 30 mm. Conclusion: The authors proposed recommendation for safe C2 pedicle and pars screw placement. These landmarks are suitable for Thai population. | en_US |
dc.subject | Medicine | en_US |
dc.title | Anatomical study of C2 pedicle and pars interarticularis in thai population | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Journal of the Medical Association of Thailand | en_US |
article.volume | 100 | en_US |
article.stream.affiliations | Mahidol University | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.