Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/57675
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEtienne M. Schönbachen_US
dc.contributor.authorVoraporn Chaikitmongkolen_US
dc.contributor.authorRachel Annamen_US
dc.contributor.authorEmma C. McDonnellen_US
dc.contributor.authorYulia Wolfsonen_US
dc.contributor.authorEmily Fletcheren_US
dc.contributor.authorHendrik P.N. Schollen_US
dc.date.accessioned2018-09-05T03:47:53Z-
dc.date.available2018-09-05T03:47:53Z-
dc.date.issued2017-07-01en_US
dc.identifier.issn14230259en_US
dc.identifier.issn00303747en_US
dc.identifier.other2-s2.0-85021086820en_US
dc.identifier.other10.1159/000475996en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85021086820&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/57675-
dc.description.abstract© 2017 S. Karger AG, Basel. Purpose: We present the multifocal electroretinogram (mfERG) with a 7-hexagon array as an objective test of macular function that can be recorded in 14 s. We provide normal values and investigate its reproducibility and validity. Methods: Healthy participants underwent mfERG testing according to International Society for Clinical Electrophysiology of Vision (ISCEV) standards using the Espion Profile/D310 multifocal ERG system (Diagnosys, LLC, Lowell, MA, USA). One standard recording of a 61-hexagon array and 2 repeated recordings of a custom 7-hexagon array were obtained. Results: A total of 13 subjects (mean age 46.9 years) were included. The median response densities were 12.5 nV/deg2 in the center and 5.2 nV/deg2 in the periphery. Intereye correlations were strong in both the center (ρCenter = 0.821; p < 0.0001) and the periphery (ρPeriphery = 0.862; p < 0.0001). Intraeye correlations were even stronger: ρCenter = 0.904 with p < 0.0001 and ρPeriphery = 0.955 with p < 0.0001. Bland-Altman plots demonstrated an acceptable retest mean difference in both the center and periphery, and narrow limits of agreement. We found strong correlations of the center (ρCenter = 0.826; p < 0.0001) and periphery (ρPeriphery = 0.848; p < 0.0001), with recordings obtained by the 61-hexagon method. Conclusions: The 7-hexagon mfERG provides reproducible results in agreement with results obtained according to the ISCEV standard.en_US
dc.subjectMedicineen_US
dc.subjectNeuroscienceen_US
dc.title7-Hexagon Multifocal Electroretinography for an Objective Functional Assessment of the Macula in 14 Secondsen_US
dc.typeJournalen_US
article.title.sourcetitleOphthalmic Researchen_US
article.volume58en_US
article.stream.affiliationsThe Wilmer Eye Institute at Johns Hopkinsen_US
article.stream.affiliationsGriffin Hospital Derbyen_US
article.stream.affiliationsUT Southwestern Medical Schoolen_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsCheltenham General Hospitalen_US
article.stream.affiliationsUniversitatsspital Baselen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.