Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/56966
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChidkamon Thunkhamraken_US
dc.contributor.authorPreeyaporn Reanpangen_US
dc.contributor.authorKontad Ounnunkaden_US
dc.contributor.authorJaroon Jakmuneeen_US
dc.date.accessioned2018-09-05T03:32:45Z-
dc.date.available2018-09-05T03:32:45Z-
dc.date.issued2017-08-15en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-85018266578en_US
dc.identifier.other10.1016/j.talanta.2017.04.058en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85018266578&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/56966-
dc.description.abstract© 2017 Elsevier B.V. Sequential injection (SI) system incorporated with amperometric immunosensor was developed for sensitive determination of human immunoglobulin G (HIgG). A cost effective label-free immunosensor was fabricated by immobilizing anti-HIgG on a graphene oxide (GO) modified screen-printed carbon electrode (SPCE). The developed electrode was characterized by cyclic voltammetry(CV), scanning electron microscope(SEM), and energy dispersive spectroscopy(EDS) which confirmed the selective immunointeraction of HIgG to the anti-HIgG on the electrode, thus reduced the amperometric current of [Fe(CN)6]3-/4-redox probe. The sensing electrode was placed in a designed electrochemical flow cell of SI system, where the redox probe was propelled through and the currents before and after the immunointeraction occurred were measured amperometrically by using a simple home-made amperometer. Under the optimum condition: flow rate of 2 mL min−1, applied potential of +350 mV, [Fe(CN)6]3-/4-concentration of 10 mM and 10 min of incubation time, a linear calibration in the range of 2–100 ng mL−1was achieved, with detection limit of 1.70 ng mL−1. The proposed system provided good repeatability and reproducibility and the application for urine sample analysis was demonstrated.en_US
dc.subjectChemistryen_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleSequential injection system with amperometric immunosensor for sensitive determination of human immunoglobulin Gen_US
dc.typeJournalen_US
article.title.sourcetitleTalantaen_US
article.volume171en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsThammasat Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.