Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/56966
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chidkamon Thunkhamrak | en_US |
dc.contributor.author | Preeyaporn Reanpang | en_US |
dc.contributor.author | Kontad Ounnunkad | en_US |
dc.contributor.author | Jaroon Jakmunee | en_US |
dc.date.accessioned | 2018-09-05T03:32:45Z | - |
dc.date.available | 2018-09-05T03:32:45Z | - |
dc.date.issued | 2017-08-15 | en_US |
dc.identifier.issn | 00399140 | en_US |
dc.identifier.other | 2-s2.0-85018266578 | en_US |
dc.identifier.other | 10.1016/j.talanta.2017.04.058 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85018266578&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/56966 | - |
dc.description.abstract | © 2017 Elsevier B.V. Sequential injection (SI) system incorporated with amperometric immunosensor was developed for sensitive determination of human immunoglobulin G (HIgG). A cost effective label-free immunosensor was fabricated by immobilizing anti-HIgG on a graphene oxide (GO) modified screen-printed carbon electrode (SPCE). The developed electrode was characterized by cyclic voltammetry(CV), scanning electron microscope(SEM), and energy dispersive spectroscopy(EDS) which confirmed the selective immunointeraction of HIgG to the anti-HIgG on the electrode, thus reduced the amperometric current of [Fe(CN)6]3-/4-redox probe. The sensing electrode was placed in a designed electrochemical flow cell of SI system, where the redox probe was propelled through and the currents before and after the immunointeraction occurred were measured amperometrically by using a simple home-made amperometer. Under the optimum condition: flow rate of 2 mL min−1, applied potential of +350 mV, [Fe(CN)6]3-/4-concentration of 10 mM and 10 min of incubation time, a linear calibration in the range of 2–100 ng mL−1was achieved, with detection limit of 1.70 ng mL−1. The proposed system provided good repeatability and reproducibility and the application for urine sample analysis was demonstrated. | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.title | Sequential injection system with amperometric immunosensor for sensitive determination of human immunoglobulin G | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Talanta | en_US |
article.volume | 171 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Thammasat University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.