Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/56778
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEmma Fortuneen_US
dc.contributor.authorJeremy Crenshawen_US
dc.contributor.authorVipul Lugadeen_US
dc.contributor.authorKenton R. Kaufmanen_US
dc.date.accessioned2018-09-05T03:30:08Z-
dc.date.available2018-09-05T03:30:08Z-
dc.date.issued2017-04-01en_US
dc.identifier.issn18734030en_US
dc.identifier.issn13504533en_US
dc.identifier.other2-s2.0-85011067828en_US
dc.identifier.other10.1016/j.medengphy.2017.01.002en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85011067828&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/56778-
dc.description.abstract© 2017 IPEM With the increasing use of instrumented force treadmills in biomechanical research, it is imperative that the validity of center of pressure (COP) measurements is established. The study aims were to compare an instrumented treadmill's static-belt COP accuracy to that of a floor-embedded platform, develop a novel method to quantify dynamic-belt COP accuracy with controlled precision and perform an initial investigation of how dynamic COP accuracy changes with weight and velocity. Static COP accuracy was assessed by applying a force while moving a rigid rod in a circular clockwise motion at nine positions of interest on the two treadmill and two ground-embedded force plates. Dynamic COP accuracy was assessed for weights (68.0, 102.1, and 136.1 kg), applied through a ball bearing of 2.54 cm circumference, with peak treadmill belt speeds of 0.5, 0.75, and 1.0 m/s. COP accuracy was assessed relative to motion capture marker trajectories. Statically, treadmill COP error was similar to that of the ground-embedded force plates and that reported for other treadmills. Dynamically, COP error appeared to vary systematically with weight and velocity and in the case of anteroposterior COP error, shear force, although testing with a larger number of weights and velocities is needed to fully define the relationship. This novel method can be used to assess any instrumented treadmill's dynamic COP accuracy with controlled precision.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectEngineeringen_US
dc.titleDynamic assessment of center of pressure measurements from an instrumented AMTI treadmill with controlled precisionen_US
dc.typeJournalen_US
article.title.sourcetitleMedical Engineering and Physicsen_US
article.volume42en_US
article.stream.affiliationsMayo Clinicen_US
article.stream.affiliationsUniversity of Delawareen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles