Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/56734
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPimporn Insainen_US
dc.contributor.authorJaroon Jakmuneeen_US
dc.date.accessioned2018-09-05T03:29:33Z-
dc.date.available2018-09-05T03:29:33Z-
dc.date.issued2017-07-01en_US
dc.identifier.issn01252526en_US
dc.identifier.other2-s2.0-85023774150en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85023774150&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/56734-
dc.description.abstract© 2017, Chiang Mai University. All rights reserved. Flow injection amperometric system has been developed for determination of phosphorus. It is based on in-line formation of 12-molybdophosphate complex, which is further electrochemically reduced on a glassy carbon working electrode at a constant applied potential of 0.20 V vs. Ag/AgCl. An electrical current is directly proportional to phosphate concentration. Calibration graphs plotting between peak height and phosphate concentration were obtained in range of 0.1-1.0 and 1.0-10.0 mg L-1P-PO4, with a detection limit of 0.03 mg L-1P-PO4. The precision of 2.1, 2.6, 1.5, 1.2 and 1.0% (n=11, 0.1, 0.5, 1.0, 5.0 and 10.0 mg L-1P-PO4, respectively) and sample throughput of 90 h-1were achieved. The method has lower interferences (i.e., from silicate, colored and colloidal substances, and the Schlieren’s effect) than the commonly used spectrophotometric method. Although it may be interfered by cations, e.g., Fe3+and Al3+, these ions could be eliminated by using Chelex 100 resin column. The proposed system was successfully applied to determine phosphorus that sequentially leached from sediments. An off-line leaching column was proposed for fractionation of phosphorus according to Hieltjes-Lijklema scheme (HLS), employing 1.0 M NH4Cl, 0.1 M NaOH, and 0.5 M HCl as extractants, respectively. The results obtained from extraction by using the proposed column method and the batch shaking method were in good agreement (no significant difference at 95% confident level).en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectMaterials Scienceen_US
dc.subjectMathematicsen_US
dc.subjectPhysics and Astronomyen_US
dc.titleFlow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sedimenten_US
dc.typeJournalen_US
article.title.sourcetitleChiang Mai Journal of Scienceen_US
article.volume44en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.