Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/56170
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKittisak Unsrisongen_US
dc.contributor.authorSiriporn Tapheyen_US
dc.contributor.authorKanokporn Oranratanachaien_US
dc.date.accessioned2018-09-05T03:10:01Z-
dc.date.available2018-09-05T03:10:01Z-
dc.date.issued2016-04-01en_US
dc.identifier.issn15475646en_US
dc.identifier.issn15475654en_US
dc.identifier.other2-s2.0-84983537830en_US
dc.identifier.other10.3171/2015.7.SPINE15319en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84983537830&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/56170-
dc.description.abstract©AANS, 2016. OBJECT: The object of this study was to evaluate the accuracy of fast 3D contrast-enhanced spinal MR angiography (MRA) using a manual syringe contrast injection technique for detecting and evaluating spinal arteriovenous shunts (AVSs). METHODS: This was a retrospective study of 15 patients and 20 spinal MRA and catheter angiography studies. The accuracy of using spinal MRA to detect spinal AVS, localize shunts, and discriminate the subtype and dominant arterial feeder of the AVS were studied. RESULTS: There were 14 pretherapeutic and 6 posttherapeutic follow-up spinal MRA and catheter spinal angiography studies. The spinal AVS was demonstrated in 17 of 20 studies. Spinal MRA demonstrated 100% sensitivity for detecting spinal AVS with no false-negative results. A 97% accuracy rate for AVS subtype discrimination and shunt level localization was achieved using this study's diagnostic criteria. The detection of the dominant arterial feeder was limited to 9 of these 17 cases (53%). CONCLUSIONS: The fast 3D contrast-enhanced MRA technique performed using manual syringe contrast injection can detect the presence of a spinal AVS, locate the shunt level, and discriminate AVS subtype in most cases, but is limited when detecting small arterial feeders.en_US
dc.subjectMedicineen_US
dc.titleSpinal arteriovenous shunts: Accuracy of shunt detection, localization, and subtype discrimination using spinal magnetic resonance angiography and manual contrast injection using a syringeen_US
dc.typeJournalen_US
article.title.sourcetitleJournal of Neurosurgery: Spineen_US
article.volume24en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.