Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/56131
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSanphat Sangudsupen_US
dc.contributor.authorTawika Kaewchuren_US
dc.contributor.authorWaralee Teeyasoontranonen_US
dc.contributor.authorPitchayaponne Klunklinen_US
dc.contributor.authorNisa Chawapunen_US
dc.contributor.authorSupoj Ua-Apisitwongen_US
dc.date.accessioned2018-09-05T03:09:24Z-
dc.date.available2018-09-05T03:09:24Z-
dc.date.issued2016-06-01en_US
dc.identifier.issn14671131en_US
dc.identifier.issn14603969en_US
dc.identifier.other2-s2.0-84964319602en_US
dc.identifier.other10.1017/S1460396916000078en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964319602&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/56131-
dc.description.abstract© Cambridge University Press 2016. Purpose: To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC). Methods: Nine NSCLC patients with PET/CT images were enrolled into this study. Gross tumour volumes (GTVs) were delineated by the PET visual assessment (PETvis), the automated PET (PETauto), standardised uptake value (SUV)>2·5 (PET2·5) and threshold 40% SUVmax (PET40), and CT-based method. For each patient, two IMRT treatment plans based on CT and PET/CT delineation were performed. The target coverage and the dose-volume parameters for organs at risk were analysed. Results: The PETauto referred to PET40 when SUVmax<7 and PET2·5 when SUVmax≥7. The mean GTVs were 15·04, 15·7 and 15·14 cc for PETauto, PETvis and CT based, respectively. The GTV of PETauto was not different from PETvis (p = 0·441) and CT based (p = 0·594). Based on CT delineation in IMRT planning, only 34% of the cases had sufficient PET/CT planning target volumes coverage, whereas the organs at risk dose parameters were not statistically significant (p>0·05). Conclusions: PET/CT enables more accurate assessment of tumour delineation for NSCLC, therefore improve target coverage in IMRT plan.en_US
dc.subjectMedicineen_US
dc.titleVolumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patientsen_US
dc.typeJournalen_US
article.title.sourcetitleJournal of Radiotherapy in Practiceen_US
article.volume15en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.