Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/55731
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPeerapong Jitsangiamen_US
dc.contributor.authorKorakod Nusiten_US
dc.contributor.authorSuphat Chummuneeraten_US
dc.contributor.authorPrinya Chindaprasirten_US
dc.contributor.authorPreda Pichayapanen_US
dc.date.accessioned2018-09-05T03:00:23Z-
dc.date.available2018-09-05T03:00:23Z-
dc.date.issued2016-10-01en_US
dc.identifier.issn08991561en_US
dc.identifier.other2-s2.0-84988640296en_US
dc.identifier.other10.1061/(ASCE)MT.1943-5533.0001601en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84988640296&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/55731-
dc.description.abstract© 2016 American Society of Civil Engineers. This paper presents an examination of the fatigue characteristics of cement-treated base (CTB), a cement-stabilized material for use in road pavement construction based on CTB beam test specimens prepared and tested under laboratory conditions. The beam fatigue protocol for asphalt concrete, following the Austroads standard test method of AG:PT/T233, were adapted to examine the fatigue characteristics of the CTB test specimens. Standard road base (Granite/Diorite) from the local quarry in Western Australia was employed as the parent material of CTB. The beam-fatigue tests were conducted under the strain-controlled (constant strain) and stress-controlled (constant stress) testing conditions with varying cement contents (3-10%) of CTB test specimens. Two different loading waveforms of sinusoidal and haversine load curves were also investigated. The results show that for the strain-controlled testing condition, the fatigue characteristics of the CTB test specimens were not affected by the difference in both loading waveforms. Furthermore, the fatigue characteristics of the CTB test specimens were significantly influenced by the levels of the applied strains. Under the strain-controlled testing condition, the test results also indicated the existence of fatigue endurance limit, which occurred based on the test condition of the applied strain level of 150 microstrains or less subjected to 5% cement specimens. This fatigue endurance limit increased with respect to higher cement content and initial cyclic flexural stiffness. For the stress-controlled testing condition, this study found that the conclusion cannot be made that a relationship exists between applied stress level and fatigue characteristic of the CTB test specimens. This is because half of the test specimens in this study were damaged in the early stages of loading cycles with small increases in applied stress levels. Considering all the test results, the strain-controlled testing was preferable, based on the test conditions and environment used in this study. This study confirms that the use of the adapted beam-fatigue test protocol of asphalt concrete is suitable to determine the CTB fatigue characteristics, which are difficult to obtain with no standard test protocol. This would lead to more effective use of this material in road pavement design and construction.en_US
dc.subjectEngineeringen_US
dc.subjectMaterials Scienceen_US
dc.titleFatigue assessment of cement-treated base for roads: An examination of beam-fatigue testsen_US
dc.typeJournalen_US
article.title.sourcetitleJournal of Materials in Civil Engineeringen_US
article.volume28en_US
article.stream.affiliationsCurtin Universityen_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsBureau of Location and Designen_US
article.stream.affiliationsKhon Kaen Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.