Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/55622
Full metadata record
DC FieldValueLanguage
dc.contributor.authorT. Paepoemsinen_US
dc.contributor.authorP. A. Reicharten_US
dc.contributor.authorP. Chaijareenonten_US
dc.contributor.authorF. P. Strietzelen_US
dc.contributor.authorPathawee Khongkhunthianen_US
dc.date.accessioned2018-09-05T02:58:55Z-
dc.date.available2018-09-05T02:58:55Z-
dc.date.issued2016-10-01en_US
dc.identifier.issn20352468en_US
dc.identifier.issn19745648en_US
dc.identifier.other2-s2.0-84997531423en_US
dc.identifier.other10.11138/orl/2016.9.4.213en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84997531423&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/55622-
dc.description.abstract© 2016 CIC Edizioni Internazionali Unauthorized reproduction of this article is prohibited. Purpose. The aim of this study was to evaluate the removal torque of three different abutment screws and pull out strength of implant-abutment connection for single implant restorations after mechanical cyclic loading. Methods. The study was performed in accordance with ISO 14801:2007. Three implant groups (n=15) were used: group A, PW Plus® with flat head screw; group B, PW Plus® with tapered screw; and group C, Conelog® with flat head screw. All groups had the same implant-abutment connection feature: cone with mandatory index. All screws were tightened with manufacturer’s recommended torque. Ten specimens in each group underwent cyclic loading (1x106 cycles, 10 Hz, and 250 N). Then, all specimens were un-tightened, measured for the removal torque, and underwent a tensile test. The force that dislodged abutment from implant fixture was recorded. The data were analysed using independent sample t-test, ANOVA and Tukey HSD test. Results. Before cyclic loading, removal torque in groups A, B and C were significantly different (B> A> C, P<.05). After cyclic loading, removal torque in all groups decreased significantly (P<.05). Group C revealed significantly less removal torque than groups A and B (P<.005). Tensile force in all groups significantly increased after cyclic loading (P<.05), group A had significantly less tensile force than groups B and C (P<.005). Conclusions. Removal torque reduced significantly after cyclic loading. Before cyclic loading, tapered screws maintained more preload than did flat head screws. After cyclic loading, tapered and flat head screws maintained even amounts of preload. The tensile force that dislodged abutment from implant fixture increased immensely after cyclic loading.en_US
dc.subjectDentistryen_US
dc.titleRemoval torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loadingen_US
dc.typeJournalen_US
article.title.sourcetitleORAL and Implantologyen_US
article.volume9en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsCharité – Universitätsmedizin Berlinen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.