Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/55518
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTeerayuth Tongbarnen_US
dc.contributor.authorBoonsri Kaewkham-Aien_US
dc.contributor.authorKasemsak Uthaichanaen_US
dc.date.accessioned2018-09-05T02:57:27Z-
dc.date.available2018-09-05T02:57:27Z-
dc.date.issued2016-06-27en_US
dc.identifier.other2-s2.0-84979538938en_US
dc.identifier.other10.1109/AQTR.2016.7501324en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84979538938&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/55518-
dc.description.abstract© 2016 IEEE. In this paper, a mathematical modeling of the flue gas path system with closed-loop controller for wet desulfurization with lime in Mae Moh coal power plant, Thailand is presented. The modeling using various polynomial structures and the parameter identification of the plant, the controller and the sensor are performed with the emphasis on the plant. Since the goal is to predict the operating condition where the system is tripped and causing the disruption in electricity generation of the plant, the validation of the model is demonstrated against the hard conditions, where rapid changes of system load causing the system tripped events occurred. Due to the limitation on the existing data acquisition system causing the low resolution on the quality of the collected data, two data treatment processes are introduced and compared, i.e., the linear interpolation with delay and the Piecewise Cubic Hermits Interpolating Polynomial (PCHIP) technique for the best performance selection. The model parameters are estimated and compared based on a least squares criteria. The controller is configured based on the adapted PI controller of the actual system. The performance of proposed system models are given in terms of root-mean-square error (RMSE). Based on the simulation results, it is found that the 2nd-order polynomial model with linear interpolation with delay is the most promising and delivers us the satisfactory performance under both normal load changing and during the tripped event.en_US
dc.subjectComputer Scienceen_US
dc.subjectEngineeringen_US
dc.titleModeling of closed-loop flue gas path system for desulfurization in power plant under severe load changing conditionsen_US
dc.typeConference Proceedingen_US
article.title.sourcetitle2016 20th IEEE International Conference on Automation, Quality and Testing, Robotics, AQTR 2016 - Proceedingsen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.