Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/55186
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Miki Kanna | en_US |
dc.contributor.author | Sarawut Somnam | en_US |
dc.contributor.author | Jaroon Jakmunee | en_US |
dc.date.accessioned | 2018-09-05T02:52:51Z | - |
dc.date.available | 2018-09-05T02:52:51Z | - |
dc.date.issued | 2016-07-01 | en_US |
dc.identifier.issn | 01252526 | en_US |
dc.identifier.other | 2-s2.0-84978634530 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84978634530&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/55186 | - |
dc.description.abstract | © 2016, Chiang Mai University. All rights reserved. In this work, a Ag/AgCl electrode was prepared from silver obtained from recovery of laboratory waste via the cementation technique. The extracted silver metal has purity of 89.4-97.0%, as examined by the Volhard’s titration. Silver was melted, poured into a cast, and elongated to be a silver wire with the size of 1 mm o.d. and length of 1.33 m. The wire was then used to prepare Ag/AgCl electrode by immerging it into a solution of FeCl3⋅6H2O to form a AgCl film on the silver wire. This electrode was used as a working electrode for chloride determination or further fabricated as a reference electrode. For reference electrode preparation, the Ag/AgCl electrode was immersed in a saturated solution of KNO3contained in a glass tube plugging with agar at one end to act as a salt bridge. The working and reference electrodes were tested for potentiometric determination of chloride. Electrical potential was plotted versus logarithm of chloride concentration to obtain two linear calibration graphs, 5-20 ppm and 20-60 ppm, with the linear equation of y = 0.0018x - 0.0347 and y = 0.0006x - 0.0121, respectively. Moreover, the precision (%RSD) examined with 1 and 20 ppm of chloride solution was 0.9% and 2.7% (n=11), respectively. The prepared electrodes were used for determination of chloride in real samples comparing the results by t-test to those determined by the precipitation titration method. It was found that both methods have no significant difference at 95% confidence level. | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Materials Science | en_US |
dc.subject | Mathematics | en_US |
dc.subject | Physics and Astronomy | en_US |
dc.title | Preparation of an economic home-made Ag/AgCl electrode from silver recovered from laboratory wastes | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Chiang Mai Journal of Science | en_US |
article.volume | 43 | en_US |
article.stream.affiliations | Chiang Mai Rajabhat University | en_US |
article.stream.affiliations | Chiang Mai University | en_US |