Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/54780
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dumnoensun Pruksakorn | en_US |
dc.contributor.author | Nattapon Chantarapanich | en_US |
dc.contributor.author | Olarn Arpornchayanon | en_US |
dc.contributor.author | Taninit Leerapun | en_US |
dc.contributor.author | Kriskrai Sitthiseripratip | en_US |
dc.contributor.author | Natapoom Vatanapatimakul | en_US |
dc.date.accessioned | 2018-09-04T10:23:23Z | - |
dc.date.available | 2018-09-04T10:23:23Z | - |
dc.date.issued | 2015-01-01 | en_US |
dc.identifier.issn | 18616429 | en_US |
dc.identifier.issn | 18616410 | en_US |
dc.identifier.other | 2-s2.0-84939877209 | en_US |
dc.identifier.other | 10.1007/s11548-014-1072-2 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939877209&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/54780 | - |
dc.description.abstract | © 2014, CARS. Purpose : To present a rapid-prototype (RP) endoprosthesis replacement after tumor resection in patients with bone metastasis of the upper extremity. The short-term complications and functional outcomes were evaluated as well as the survival of patients and endoprosthesis.Methods : Bone metastasis patients who required bone resection and endoprosthesis replacement were enrolled and consented before operation. Custom-made endoprosthesis was fabricated from polymethyl methacrylate assisted by RP technology. After surgery was performed, patients were followed up daily until discharge and monthly until 6 months postoperatively for immediate post-operative complications and for signs of endoprosthesis failure. The functional outcome was evaluated 6 months postoperatively by the Musculoskeletal Tumor Society score (MTSS) and the Mankin score. Thereafter, patients’ survival and arm condition were monitored every 3 months.Results : Sixteen cases participated on this study. There were nine proximal-, four total- and two distal humerus, and one proximal ulna replacement. The median follow-up period was 486 days. The mean MTSS was 55 % and the Mankin score was good in 64 % and fair in 36 % of the patients. Glenohumeral subluxation was observed in 23 % of the patients; however, a stable shoulder was achieved in all cases. There were no prosthesis failure or systemic breakage.Conclusions : An RP endoprosthesis may have significant advantages when the entire humerus needs to be replaced, or periarticular sites are involved. This technique offers custom-made endoprosthesis with enough durability, and in a relatively short production time at reasonable costs which are suitable for palliative reconstruction. | en_US |
dc.subject | Medicine | en_US |
dc.title | Rapid-prototype endoprosthesis for palliative reconstruction of an upper extremity after resection of bone metastasis | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | International Journal of Computer Assisted Radiology and Surgery | en_US |
article.volume | 10 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Kasetsart University | en_US |
article.stream.affiliations | Thailand National Metal and Materials Technology Center | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.