Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/51108
Full metadata record
DC FieldValueLanguage
dc.contributor.authorT. Apivatthakakulen_US
dc.contributor.authorS. Patiyasikanen_US
dc.contributor.authorS. Luevitoonvechkiten_US
dc.date.accessioned2018-09-04T04:51:43Z-
dc.date.available2018-09-04T04:51:43Z-
dc.date.issued2010-02-01en_US
dc.identifier.issn00201383en_US
dc.identifier.other2-s2.0-74449087057en_US
dc.identifier.other10.1016/j.injury.2009.08.002en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=74449087057&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/51108-
dc.description.abstractSeveral recent reports have described the minimally invasive plate osteosynthesis (MIPO) technique in the treatment of humeral shaft fractures by the anterior approach. The purpose of this study is to identify the danger zone for locking screw placement to avoid musculocutaneous nerve injury in the anterior compartment and radial nerve injury in the posterior compartment of the humerus relative to the humeral length. Eighteen arms of fresh cadavers were fixed with 10-hole locking compression plate (LCP) by anterior approach using the MIPO technique. Two locking screws on each end were fixed by the open technique; the rest of the screws were inserted percutaneously. The arms were dissected both anterior and posterior to identify musculocutaneous and radial nerve injuries. Humeral length with a simple palpable bony landmark was measured from the posterior tip of the acromion process to the lateral epicondyle. Damage or direct contact of the locking screws to the musculocutaneous or radial nerve was recorded, and the distance between the screws and the radial nerve was measured. The average humeral length was 29.71 cm (99% confidence interval (CI): 28.54-30.86 cm). The danger zone for the musculocutaneous nerve averaged 18.37% (99% CI: 17.06-19.60) to 42.67% (99% CI: 42.33-43.03) of the humeral length from the lateral epicondyle. The danger zone for the radial nerve averaged 36.35% (99% CI: 35.81-37.07) to 59.20% (99% CI: 59.00-59.46) of the humeral length, and the most dangerous screws that penetrated or touched the radial nerve lay 47.22% (99% CI: 45.27-49.17) to 53.21% (99% CI: 51.16-55.33) of the humeral length from the lateral epicondyle. An anteroposterior locking screw placed percutaneously endangered the musculocutaneous and radial nerves. From this cadaveric study, the danger zone for the musculocutaneous and radial nerves could be determined as a percentage of the humeral length. Since the zone with radial nerve injuries shows a large variation, this procedure should only be done by experienced surgeons. © 2009 Elsevier Ltd. All rights reserved.en_US
dc.subjectMedicineen_US
dc.titleDanger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: A cadaveric studyen_US
dc.typeJournalen_US
article.title.sourcetitleInjuryen_US
article.volume41en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.