Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/50406
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pawinee Thongsrisomboon | en_US |
dc.contributor.author | Boonsom Liawruangrath | en_US |
dc.contributor.author | Saisunee Liawruangrath | en_US |
dc.contributor.author | Sakchai Satienperakul | en_US |
dc.date.accessioned | 2018-09-04T04:40:45Z | - |
dc.date.available | 2018-09-04T04:40:45Z | - |
dc.date.issued | 2010-12-01 | en_US |
dc.identifier.issn | 03088146 | en_US |
dc.identifier.other | 2-s2.0-77954625328 | en_US |
dc.identifier.other | 10.1016/j.foodchem.2010.05.018 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954625328&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/50406 | - |
dc.description.abstract | A simple flow injection chemiluminescence (FI-CL) method was developed for the rapid and sensitive determination of nitrofurans, including furazolidone, nitrofurantoin and nitrofurazone, in animal feeds based on its chemiluminescence induced by potassium permanganate in sulphuric acid medium. The method involves the injection of nitrofuran samples or standards into H2SO4carrier stream, which then merges at a T-piece with a reagent stream consisting of KMnO4in the H2SO4carrier solution. The elicited chemiluminescence intensity of the resulting reaction mixture was measured by photomultiplier tube operated at a voltage of 950V. Optimum CL signals were given using 2.5×10-5molL-1potassium permanganate in 0.1molL-1sulphuric acid as an oxidant stream and a carrier stream of 0.1molL-1sulphuric acid with a total flow rate of 7.0mLmin-1. Results detailing the optimisation of the analytical signal, calibration, and common interferences of animal feeds were also discussed. The proposed FI-CL method was successfully applied to the determination of nitrofurans in animal feeds, with excellent recoveries, as the determination is free from interference. The method validation has been compared versus HPLC method for animal feed samples. © 2010 Elsevier Ltd. | en_US |
dc.subject | Agricultural and Biological Sciences | en_US |
dc.subject | Chemistry | en_US |
dc.title | Determination of nitrofurans residues in animal feeds by flow injection chemiluminescence procedure | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Food Chemistry | en_US |
article.volume | 123 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Maejo University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.