Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49704
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sakorn Pornprasert | en_US |
dc.contributor.author | Thanatcha Wiengkum | en_US |
dc.contributor.author | Sarinee Srithep | en_US |
dc.contributor.author | Isarapong Chainoi | en_US |
dc.contributor.author | Panthong Singboottra | en_US |
dc.contributor.author | Sanchai Wongwiwatthananukit | en_US |
dc.date.accessioned | 2018-09-04T04:05:47Z | - |
dc.date.available | 2018-09-04T04:05:47Z | - |
dc.date.issued | 2011-07-01 | en_US |
dc.identifier.issn | 15986535 | en_US |
dc.identifier.other | 2-s2.0-79961076404 | en_US |
dc.identifier.other | 10.3343/kjlm.2011.31.3.138 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79961076404&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/49704 | - |
dc.description.abstract | Background: Prevention and control of thalassemia requires simple, rapid, and accurate screening tests for carrier couples who are at risk of conceiving fetuses with severe thalassemia. Methods: Single-tube multiplex real-time PCR with SYBR Green1 and high-resolution melting (HRM) analysis were used for the identification of α-thalassemia-1 Southeast Asian (SEA) and Thai type deletions and β-thalassemia 3.5-kb gene deletion.The results were compared with those obtained using conventional gap-PCR. DNA samples were derived from 28 normal individuals, 11 individuals with α-thalassemia-1 SEA type deletion, 2 with α-thalassemia-1 Thai type deletion, and 2 with heterozygous β-thalassemia 3.5-kb gene deletion. Results: HRM analysis indicated that the amplified fragments from α-thalassemia-1 SEA type deletion, α-thalassemia-1 Thai type deletion, β-thalassemia 3.5-kb gene deletion, and the wild-type β-globin gene had specific peak heights at mean melting temperature (T m) values of 86.89°C, 85.66°C, 77.24°C, and 74.92°C, respectively. The results obtained using single-tube multiplex real-time PCR with SYBR Green1 and HRM analysis showed 100% consistency with those obtained using conventional gap-PCR. Conclusions: Single-tube multiplex real-time PCR with SYBR Green1 and HRM analysis is a potential alternative for routine clinical screening of the common types of α- and β-thalassemia large gene deletions, since it is simple, cost-effective, and highly accurate. © The Korean Society for Laboratory Medicine. | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Medicine | en_US |
dc.title | Detection of α-thalassemia-1 Southeast Asian and Thai type deletions and β-thalassemia 3.5-kb deletion by single-tube multiplex real-time PCR with SYBR green 1 and high-resolution melting analysis | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Korean Journal of Laboratory Medicine | en_US |
article.volume | 31 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Lamphun Hospital | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.